This MedLibrary.org supplementary page on Arteriovenous fistula is provided directly from the open source Wikipedia as a service to our readers. Please see the note below on authorship of this content, as well as the Wikipedia usage guidelines. To search for other content from our encyclopedia supplement, please use the form below:

Arteriovenous fistula
Classification and external resources
ICD-10 I28.0, I77.0
ICD-9 414.19, 417.0, 447.0, 747.3
DiseasesDB 32435
eMedicine med/169 
MeSH D001164

An arteriovenous fistula is an abnormal connection or passageway between an artery and a vein. It may be congenital, surgically created for hemodialysis treatments, or acquired due to pathologic process, such as trauma or erosion of an arterial aneurysm.

Contents

Vascular access for hemodialysis

Main article: Cimino fistula
A radiocephalic fistula.

Patients with end stage renal failure are treated with hemodialysis. In dialysis, blood is withdrawn from an artery or vein, purified, and returned to a vein. The volume of blood is too great for veins to handle, so a vein must be enlarged. An artery and vein, usually in the arm above or below the elbow, are sewn together, to create a fistula, and arterial pressure eventually enlarges the vein. The enlarged vein can accommodate a cannula or large needle.

Pathophysiology

When an arteriovenous fistula is formed involving a major artery like the abdominal aorta, it can lead to a large decrease in peripheral resistance. This lowered peripheral resistance causes the heart to increase cardiac output in order to maintain proper blood flow to all tissues. The physical manifestations of this would be a relatively normal systolic blood pressure with a decreased diastolic blood pressure resulting in a wide (large) pulse pressure.

Normal blood flow in the brachial artery is 85 to 110 milliliters per minute (mL/min). After the creation of a fistula, the blood flow increases to 400 to 500 mL/min immediately, and 700 to 1,000 mL/min within 1 month. A bracheocephalic fistula above the elbow has a greater flow rate than a radiocephalic fistula at the wrist. Both the artery and the vein dilate and elongate in response to the greater blood flow and shear stress, but the vein dilates more and becomes "arterialized". In one study, the cephalic vein increased from 2.3 mm to 6.3 mm diameter after 2 months. When the vein is large enough to allow cannulation, the fistula is defined as "mature." 1

Treatment

Congenital fistulas, if small, usually do not need treatment.citation needed Acquired fistulas can be treated by surgery.

See also

References

  1. ^ Vascular, Vol. 14, Supl. 1, Nov. 2006, p. S1

External links

Wikipedia content modification information:

  • This page was last modified on 28 September 2008, at 05:04.

Wikipedia Authorship and Review

Wikipedia content provided here is not reviewed directly by MedLibrary.org. Wikipedia content is authored by an open community of volunteers and is not produced by or in any way affiliated with MedLibrary.org.

Wikipedia Usage Guidelines

This article is licensed under the GNU Free Documentation License. It uses material from the Wikipedia article on "Arteriovenous fistula".

The URL for this specific entry is:

All Wikipedia text is available under the terms of the GNU Free Documentation License. (See Copyrights for details). Wikipedia® is a registered trademark of the Wikimedia Foundation, Inc.