This MedLibrary.org supplementary page on CAT 5 is provided directly from the open source Wikipedia as a service to our readers. Please see the note below on authorship of this content, as well as the Wikipedia usage guidelines. To search for other content from our encyclopedia supplement, please use the form below:
Related Sponsors
Category 5 cable, commonly known as Cat 5, is a twisted pair (4 pairs) cable type designed for high signal integrity. Many such cables are unshielded but some are shielded. Category 5 has been superseded by the Category 5e specification. This type of cable is often used in structured cabling for computer networks such as Ethernet, and is also used to carry many other signals such as basic voice services, token ring, and ATM (at up to 155 Mbit/s, over short distances).
Contents |
Usage and wiring methods
|
||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||
Category 5
The specification for category 5 cable was defined in ANSI/TIA/EIA-568-A, with clarification in TSB-95. These documents specified performance characteristics and test requirements for frequencies of up to 100 MHz.
Category 5 cable includes four twisted pairs in a single cable jacket. This use of balanced lines helps preserve a high signal-to-noise ratio despite interference from both external sources and other pairs (this latter form of interference is called crosstalk). It is most commonly used for 100 Mbit/s networks, such as 100BASE-TX Ethernet, although IEEE 802.3ab defines standards for 1000BASE-T - Gigabit Ethernet over category 5 cable. Cat 5 cable typically has three twists per inch of each twisted pair of 24 gauge copper wires within the cables.
Category 5e
Cat 5 e cable is an enhanced version of Cat 5 that adds specifications for far end crosstalk. It was formally defined in 2001 as the TIA/EIA-568-B standard, which no longer recognizes the original Cat 5 specification. Although 1000BASE-T was designed for use with Cat 5 cable, the tighter specifications associated with Cat 5e cable and connectors make it an excellent choice for use with 1000BASE-T. Despite the stricter performance specifications, Cat 5e cable does not enable longer cable distances for Ethernet networks: cables are still limited to a maximum of 100 m (328 ft) in length (normal practice is to limit fixed ("horizontal") cables to 90 m to allow for up to 5 m of patch cable at each end, this comes to a total of the previous mentioned 100m maximum). Cat 5e cable performance characteristics and test methods are defined in TIA/EIA-568-B.2-2001.
Connectors and other information
The cable exists in both stranded and solid conductor forms. The stranded form is more flexible and withstands more bending without breaking and is suited for reliable connections with insulation piercing connectors, but makes unreliable connections in insulation-displacement connectors. The solid form is less expensive and makes reliable connections into insulation displacement connectors, but makes unreliable connections in insulation piercing connectors. Taking these things into account, building wiring (for example, the wiring inside the wall that connects a wall socket to a central patch panel) is solid core, while patch cables (for example, the movable cable that plugs into the wall socket on one end and a computer on the other) are stranded. Outer insulation is typically PVC or LSOH.
Cable types, connector types and cabling topologies are defined by TIA/EIA-568-B. Nearly always, 8P8C modular connectors, often incorrectly referred to as "RJ-45", are used for connecting category 5 cable. The specific category of cable in use can be identified by the printing on the side of the cable.1
The cable is terminated in either the T568A scheme or the T568B scheme. It doesn't make any difference which is used as they are both straight through (pin 1 to 1, pin 2 to 2, etc); however mixed cable types should not be connected in series as the impedance per pair differs slightly and could cause signal degradation. The article Ethernet over twisted pair describes how the cable is used for Ethernet, including special "cross over" cables.
Bending radius
Most Cat.5 cables can be bent at a radius approximately 4 times the diameter of the cable. 2
Electrical characteristics for Cat.5e UTP
| Property | Nominal Value | Tolerance | Unit |
|---|---|---|---|
| Characteristic impedance @ 100 MHz | 100 | ± 15 |
|
| Nominal characteristic impedance @ 100 MHz | 100 | ± 5 |
|
| DC-Loop resistance | ≤ 0.188 |
|
|
| Velocity ratio | 0.64 |
|
|
| Propagation delay | 4.80-5.30 |
|
|
| Delay skew | <0.20 |
|
|
| Capacitance | 52 |
|
|
| Max tensile load, during installation | 100 |
|
|
| Wiresize | AWG-24 (0.205 mm²) | ||
| Maximum current per conductor | 0,577 |
|
|
| Temperature operating | -55 to +60 |
|
References
- ^ Ethernet Cable Identification and Use
- ^ "Selecting coax and twisted-pair cable - Electronic Products". 081216 www2.electronicproducts.com
- ^ "SuperCat OUTDOOR CAT 5e U/UTP". 080319 draka.com
- ^ "American Wire Gauge table and AWG Electrical Current Load Limits". 081220 powerstream.com
See also
Further reading
|
||||||||
Wikipedia content modification information:
- This page was last modified on 4 January 2009, at 20:19.
Wikipedia Authorship and Review
Wikipedia content provided here is not reviewed directly by MedLibrary.org. Wikipedia content is authored by an open community of volunteers and is not produced by or in any way affiliated with MedLibrary.org.
Wikipedia Usage Guidelines
This article is licensed under the GNU Free Documentation License. It uses material from the Wikipedia article on "CAT 5".
The URL for this specific entry is:
All Wikipedia text is available under the terms of the GNU Free Documentation License. (See Copyrights for details). Wikipedia® is a registered trademark of the Wikimedia Foundation, Inc.

