This MedLibrary.org supplementary page on Flash evaporation is provided directly from the open source Wikipedia as a service to our readers. Please see the note below on authorship of this content, as well as the Wikipedia usage guidelines. To search for other content from our encyclopedia supplement, please use the form below:

A typical flash drum
A typical flash drum

Flash (or partial) evaporation is the partial vaporization that occurs when a saturated liquid stream undergoes a reduction in pressure by passing through a throttling valve or other throttling device. This process is one of the simplest unit operations. If the throttling valve or device is located at the entry into a pressure vessel so that the flash evaporation occurs within the vessel, then the vessel is often referred to as a flash drum.

If the saturated liquid is a single-component liquid (for example, liquid propane or liquid ammonia), a part of the liquid immediately "flashes" into vapor. Both the vapor and the residual liquid are cooled to the saturation temperature of the liquid at the reduced pressure. This is often referred to as "auto-refrigeration" and is the basis of most conventional vapor compression refrigeration systems.

If the saturated liquid is a multi-component liquid (for example, a mixture of propane, isobutane and normal butane), the flashed vapor is richer in the more volatile components than is the remaining liquid.

Contents

Flash evaporation of a single-component liquid

The flash evaporation of a single-component liquid is an isenthalpic (i.e., constant enthalpy) process and is often referred to as an adiabatic flash. The following equation, derived from a simple heat balance around the throttling valve or device, is used to predict how much of a single-component liquid is vaporized.

X = 100 ( HuL – HdL ) ÷ ( HdV – HdL )
where:  
X =  weight percent vaporized
HuL =  upstream liquid enthalpy at upstream temperature and pressure, J/kg
HdV
 
=  flashed vapor enthalpy at downstream pressure and corresponding saturation
    temperature, J/kg
HdL
 
=  residual liquid enthalpy at downstream pressure and corresponding saturation
    temperature, J/kg

If the enthalpy data required for the above equation is unavailable, then the following equation may be used.

X = 100 · cp ( Tu – Td ) ÷ Hv
where:  
X =  weight percent vaporized
cp =  liquid specific heat at upstream temperature and pressure, J/(kg °C)
Tu =  upstream liquid temperature, °C
Td =  liquid saturation temperature corresponding to the downstream pressure, °C
Hv
 
=  liquid heat of vaporization at downstream pressure and corresponding saturation
    temperature, J/kg

( Note: The words "upstream" and "downstream" refer to before and after the liquid passes through the throttling valve or device.)

This type of flash evaporation is used in the desalination of brackish water or ocean water by "Multi-Stage Flash Distillation." The water is heated and then routed into a reduced-pressure flash evaporation "stage" where some of the water flashes into steam. This steam is subsequently condensed into salt-free water. The residual salty liquid from that first stage is introduced into a second flash evaporation stage at a pressure lower than the first stage pressure. More water is flashed into steam which is also subsequently condensed into more salt-free water. This sequential use of multiple flash evaporation stages is continued until the design objectives of the system are met. A large part of the world's installed desalination capacity uses multi-stage flash distillation. Typically such plants have 24 or more sequential stages of flash evaporation.

Equilibrium flash of a multi-component liquid

The equilibrium flash of a multi-component liquid may be visualized as a simple distillation process using a single equilibrium stage. It is very different and more complex than the flash evaporation of single-component liquid. For a multi-component liquid, calculating the amounts of flashed vapor and residual liquid in equilibrium with each other at a given temperature and pressure requires a trial-and-error iterative solution. Such a calculation is commonly referred to as an equilibrium flash calculation. It involves solving the Rachford-Rice equation:[1]

\sum_i\frac{z_i \, (K_i - 1)}{1 + \beta \, (K_i - 1)}=0

where:

  • zi is the mole fraction of component i in the feed liquid (assumed to be known);
  • β is the fraction of feed that is vaporised;
  • Ki is the equilibrium constant of component i.

The equilibrium constants Ki are in general functions of many parameters, though the most important is arguably temperature; they are defined as:

y_i = K_i \, x_i

where:

  • xi is the mole fraction of component i in liquid phase;
  • yi is the mole fraction of component i in gas phase.

Once the Rachford-Rice equation has been solved for β, the compositions xi and yi can be immediately calculated as:

\begin{align}
       x_i &= \frac{z_i}{1+\beta(K_i-1)}\\
       y_i &= K_i\,x_i.
       \end{align}

The Rachford-Rice equation can have multiple solutions for β, only one of which guarantees that all xi and yi will be positive. In particular, it will be the only β for which:

\frac{1}{1-K_\text{max}} = \beta_\text{min} < \beta < \beta_\text{max} = \frac{1}{1-K_\text{min}}.

It is possible to use Newton's method for solving the above Rachford-Rice equation, but there is a risk of converging to the wrong value of β; it is important to initialise the solver to a sensible initial value, such as (βmax+βmin)/2 (which is however not sufficient: Newton's method makes no guarantees on stability), or, alternatively, use a bracketing solver such as the bisection method or the Brent method, which are guaranteed to converge but can be less computationally performing.

The equilibrium flash of multi-component liquids is very widely utilized in petroleum refineries, petrochemical and chemical plants and natural gas processing plants.

Spray drying

Spray drying is the rapid drying of a slurry of very small solids suspended in a liquid. The slurry is first atomized into very small liquid droplets which are then sprayed into a stream of hot dry air. The liquid rapidly evaporates leaving behind dry powder or dry solid granules. The dry powder or solid granules are recovered from the exhaust air by using cyclones, bag filters or electrostatic precipitators.

A brief explanation of spray drying has been included here because some readers may consider spray drying to be a form of flash evaporation. However, although it is a form of liquid evaporation, it is quite different from flash evaporation.

See also

References

  1. ^ Curtis H. Whitson, Michael L. Michelsen, The Negative Flash, Fluid Phase Equilibria, 53 (1989) 51–71.

External links

Wikipedia content modification information:

  • This page was last modified on 9 October 2008, at 17:08.

Wikipedia Authorship and Review

Wikipedia content provided here is not reviewed directly by MedLibrary.org. Wikipedia content is authored by an open community of volunteers and is not produced by or in any way affiliated with MedLibrary.org.

Wikipedia Usage Guidelines

This article is licensed under the GNU Free Documentation License. It uses material from the Wikipedia article on "Flash evaporation".

The URL for this specific entry is:

All Wikipedia text is available under the terms of the GNU Free Documentation License. (See Copyrights for details). Wikipedia® is a registered trademark of the Wikimedia Foundation, Inc.