Perfusion

This MedLibrary.org supplementary page on Perfusion is provided directly from the open source Wikipedia as a service to our readers. Please see the note below on authorship of this content, as well as the Wikipedia usage guidelines. To search for other content from our encyclopedia supplement, please use the form below:

In physiology, perfusion is the process of nutritive delivery of arterial blood to a capillary bed in the biological tissue. The word is derived from the French verb "perfuser" meaning to "pour over or through."

Tests of adequate perfusion are a part of patient triage performed by medical or emergency personnel in a mass casualty incident.

Contents

Calculation

Perfusion ("F") can be measured with the following formula, where Pa is mean arterial pressure, Pv is mean venous pressure, and R is vascular resistance: [1]

F =  \frac{ P_A - P_V }{ R }

The term "Pa - Pv" is sometimes presented as "ΔP", for the change in pressure.[2]

The terms "perfusion" and "perfusion pressure" are sometimes used interchangeably, but the equation should make clear that resistance can have an effect on the perfusion, but not on the perfusion pressure.

Overperfusion and underperfusion

The terms "overperfusion" and "underperfusion" are measured relative to the average level of perfusion across all tissues in an individual body, and the terms should not be confused with hypoperfusion and "hyperperfusion", which measure the perfusion level to the tissue's current need.

Tissues like the skin are considered overperfused and receive more blood than would be expected to meet the metabolic needs of the tissue. In the case of the skin, extra blood flow is used for thermoregulation. In addition to delivering oxygen, the blood helps dissipate heat by redirecting warm blood close to the surface where it can cool the body through the sweating and thermal radiation.

Measurement using MRI

Two main categories of magnetic resonance imaging (MRI) techniques can be used to measure tissue perfusion in vivo.

  • The first is based on the use of injected contrast agent that changes the magnetic susceptibility of blood and thereby the MR signal which is repeatedly measured during bolus passage.
  • The other category is based on arterial spin labeling (ASL), where arterial blood is magnetically tagged before it enters into the tissue of interest and the amount of labeling is measured and compared to a control recording obtained without spin labeling.

See also

References

  1. ^ Richard E. Klabunde. "Cardiovascular Physiology Concepts". Retrieved on 9/12/06.
  2. ^ Physiology at MCG 7/7ch04/7ch04p26 - "Renal Perfusion Pressure and Vascular Resistance"

External links

Wikipedia content modification information:

  • This page was last modified on 16 August 2008, at 00:58.

Wikipedia Authorship and Review

Wikipedia content provided here is not reviewed directly by MedLibrary.org. Wikipedia content is authored by an open community of volunteers and is not produced by or in any way affiliated with MedLibrary.org.

Wikipedia Usage Guidelines

This article is licensed under the GNU Free Documentation License. It uses material from the Wikipedia article on "Perfusion".

The URL for this specific entry is:

All Wikipedia text is available under the terms of the GNU Free Documentation License. (See Copyrights for details). Wikipedia® is a registered trademark of the Wikimedia Foundation, Inc.