This MedLibrary.org supplementary page on Sewer gas destructor lamp is provided directly from the open source Wikipedia as a service to our readers. Please see the note below on authorship of this content, as well as the Wikipedia usage guidelines. To search for other content from our encyclopedia supplement, please use the form below:
Related Sponsors
The main purpose of a sewer gas destructor lamp is to remove sewer gases and their hazards.
Contents |
Background
Biogas forming in sewers via anaerobic digestion can be a potentially smelly and explosive hazard (chiefly due to methane). Unlike ordinary gas lamps for street lighting, the main purpose of sewer gas destructor lamps is to remove sewer gases and their hazards. Joseph Edmund Webb of Birmingham patented a sewer gas destructor lamp.citation needed
Many of these lamps were installed in the UK in towns and cities such as Sheffield, Winchester and Blyth, Northumberland. With a flame generated by burning town gas, sewer gases were drawn from the sewer below and burnt off along with the town gas to produce mainly carbon dioxide.
Improvements
JE Webb addressed a number of problems of the lamps with further patents. His patent GB189408193,[1] approved 2-March-1895, stated:
It has also been found that when the gases are drawn out from the sewer by the burning of ordinary gas a sudden flushing of the sewer might prevent any sewer gas from escaping, and thus momentarily cause the gas jets to be extinguished.
In order to solve this problem the patent specifies an arrangement of burners, air supply and heat reflection designed to produce an intense heat at the point of combustion. (Webb suggests 600 to 800 degrees Fahrenheit).
In Sheffield
The lamps were installed at places where sewer gases were likely to collect, such as at the tops of hills. The city of Sheffield, being a hilly area, had many sewer gas destructor lamps and many remain.
Sheffield on the Net has a section on the old gas lamps, which states:
Eighty-four of these street lamps were erected in Sheffield between 1914 and 1935, the largest number in any British town, due mainly to the many hills in the area where gas could be trapped.[2]
The Sheffield Star newspaper reported a local survey of the lamps by W Jessop.[3] This survey found 22 remaining lamps in Sheffield.
Current justification of the lamps
Although many of the existing lamps in Sheffield and elsewhere are now disused, the lamps still have a use today in reducing the hazards of explosion and also perhaps in reducing the greenhouse effect by stopping methane escaping into the atmosphere. The sewer gas destructor lamps convert methane (a potent greenhouse gas) from the sewers into carbon dioxide (a lesser greenhouse gas).
References
- ^ Patent Number GB189408193; Application Number 8193, 25 April, 1894; Complete Specification Left 24 January 1895; Accepted 2 March, 1895. Joseph Edmund Webb of 223 New John Street West, Hockley, Birmingham, Builder and Contractor
- ^ Sheffield on the Net - City Curiosities
- ^ Dunn, Sarah (2008), Wilf noses out locations of old gas lamps, in The Diary, Sheffield Star, 16/July/2008
External links
- The City of Winchester, UK
- Photo of lamp in Seaton Delaval, Northumberland, UK
Wikipedia content modification information:
- This page was last modified on 6 October 2008, at 03:14.
Wikipedia Authorship and Review
Wikipedia content provided here is not reviewed directly by MedLibrary.org. Wikipedia content is authored by an open community of volunteers and is not produced by or in any way affiliated with MedLibrary.org.
Wikipedia Usage Guidelines
This article is licensed under the GNU Free Documentation License. It uses material from the Wikipedia article on "Sewer gas destructor lamp".
The URL for this specific entry is:
All Wikipedia text is available under the terms of the GNU Free Documentation License. (See Copyrights for details). Wikipedia® is a registered trademark of the Wikimedia Foundation, Inc.