This MedLibrary.org supplementary page on Time constant is provided directly from the open source Wikipedia as a service to our readers. Please see the note below on authorship of this content, as well as the Wikipedia usage guidelines. To search for other content from our encyclopedia supplement, please use the form below:
Related Sponsors
In physics and engineering, the time constant usually denoted by the Greek letter τ, (tau), characterizes the frequency response of a first-order, linear time-invariant (LTI) system. Examples include electrical RC circuits and RL circuits. It is also used to characterize the frequency response of various signal processing systems – magnetic tapes, radio transmitters and receivers, record cutting and replay equipment, and digital filters – which can be modeled or approximated by first-order LTI systems.
Other examples include time constant used in control systems for integral and derivative action controllers, which are often pneumatic, rather than electrical.
Physically, the constant represents the time it takes the system's step response to reach approximately 63% of its final (asymptotic) value.
Contents |
Differential equation
First order LTI systems are characterized by the differential equation
where
represents the exponential decay constant and V is a function of time t
The time constant is related to the exponential decay constant by
General Solution
The general solution to the differential equation is
where
is the initial value of V.
Control Engineering
The diagram below depicts the exponential function y = Aeat in the specific case where a < 0, otherwise referred to as a "decaying" exponential function:
Suppose
then
The term τ (tau) is referred to as the "time constant" and can be used (as in this case) to indicate how rapidly an exponential function decays.
Where:
- t = time (generally always t > 0 in control engineering)
- A = initial value (see "specific cases" below).
Specific cases
- 1). Let t = 0, hence y = Ae0, and so y = A
- 2). Let t = τ, hence y = Ae − 1, ≈ 0.37A
- 3). Let
, and so 
- 4). Let t = 5τ, hence y = Ae − 5, ≈ 0.0067A
After a period of one time constant the function reaches e-1 = approximately 37% of its initial value. In case 4, after five time constants the function reaches a value less than 1% of its original. In most cases this 1% threshold is considered sufficient to assume that the function has decayed to zero - Hence in control engineering a stable system is mostly assumed to have settled after five time constants.
Examples of time constants
Time constants in electrical circuits
In an RL circuit, the time constant τ (in seconds) is
where R is the resistance (in ohms) and L is the inductance (in henries).
Similarly, in an RC circuit, the time constant τ (in seconds) is:
where R is the resistance (in ohms) and C is the capacitance (in farads).
Thermal time constant
See discussion page.
Time constants in neurobiology
In an action potential (or even in a passive spread of signal) in a neuron, the time constant τ is
where rm is the resistance across the membrane and cm is the capacitance of the membrane.
The resistance across the membrane is a function of the number of open ion channels and the capacitance is a function of the properties of the lipid bilayer.
The time constant is used to describe the rise and fall of the action potential, where the rise is described by
and the fall is described by
Where voltage is in millivolts, time is in seconds, and τ is in seconds.
Vmax is defined as the maximum voltage attained in the action potential, where
where rm is the resistance across the membrane and I is the current flow.
Setting for t = τ for the rise sets V(t) equal to 0.63Vmax. This means that the time constant is the time elapsed after 63% of Vmax has been reached.
Setting for t = τ for the fall sets V(t) equal to 0.37Vmax, meaning that the time constant is the time elapsed after it has fallen to 37% of Vmax.
The larger a time constant is, the slower the rise or fall of the potential of neuron. A long time constant can result in temporal summation, or the algebraic summation of repeated potentials.
Radioactive half-life
The half-life THL of a radioactive isotope is related to the exponential time constant τ by
Step Response with Non-Zero Initial Conditions
If the motor is initially spinning at a constant speed (expressed by voltage), the time constant τ is 63% of
minus Vo.
Therefore,
can be used where the initial and final voltages, respectively, are:
and
Step Response from Rest
From rest, the voltage equation is a simplification of the case with non-zero ICs. With an initial velocity of zero, V0 drops out and the resulting equation is:
The time constant will remain the same for the same system regardless of the starting conditions. For example, if an electric motor reaches 63% of its final speed from rest in ⅛ of a second, it will also take ⅛ of a second for the motor to reach 63% of its final speed when started with some non-zero initial speed. Simply stated, a system will require a certain amount of time to reach its final, steady-state situation regardless of how close it is to that value when started.
See also
External links
- Conversion of time constant τ to cutoff frequency fc and vice versa
- All about circuits - Voltage and current calculations
Wikipedia content modification information:
- This page was last modified on 4 August 2008, at 14:08.
Wikipedia Authorship and Review
Wikipedia content provided here is not reviewed directly by MedLibrary.org. Wikipedia content is authored by an open community of volunteers and is not produced by or in any way affiliated with MedLibrary.org.
Wikipedia Usage Guidelines
This article is licensed under the GNU Free Documentation License. It uses material from the Wikipedia article on "Time constant".
The URL for this specific entry is:
All Wikipedia text is available under the terms of the GNU Free Documentation License. (See Copyrights for details). Wikipedia® is a registered trademark of the Wikimedia Foundation, Inc.