This MedLibrary.org supplementary page on Wobbe index is provided directly from the open source Wikipedia as a service to our readers. Please see the note below on authorship of this content, as well as the Wikipedia usage guidelines. To search for other content from our encyclopedia supplement, please use the form below:
Related Sponsors
The Wobbe Index (WI) is an indicator of the interchangeability of fuel gases such as natural gas, liquified petroleum gas (LPG), and Town Gas and is frequently defined in the specifications of gas supply and transport utilities. If VC is the higher heating value, or calorific value, and GS is the specific gravity, the Wobbe Index, IW, is defined as

- That is, Wobbe Index = higher heating value/(square root of gas specific gravity).
The Wobbe Index is used to compare the combustion energy output of different composition fuel gases in an appliance (fire, cooker etc.). If two fuels have identical Wobbe Indices then for given pressure and valve settings the energy output will also be identical. Typically variations of up to 5% are allowed as these would not be noticeable to the consumer. The Wobbe Index is a critical factor to minimise the impact of the changeover when analyzing the use of SNG fuels such as propane-air mixtures.
Wobbe Index (kcal per standard cubic meter) of common fuel gases
| Fuel Gas | Upper Index | Lower Index |
| Hydrogen | 11,528 | 9,715 |
| Methane | 12,735 | 11,452 |
| Ethane | 16,298 | 14,931 |
| Ethylene | 15,253 | 14,344 |
| Natural gas | 12,837 | 11,597 |
| Propane | 19,376 | 17,817 |
| Propylene | 18,413 | 17,180 |
| n-butane | 22,066 | 20,336 |
| Iso-butane | 21,980 | 20,247 |
| Butylene-1 | 21,142 | 19,728 |
| LPG | 20,755 | 19,106 |
| Acetylene | 14,655 | 14,141 |
| Carbon monoxide | 3,060 | 3,060 |
Usage
The Wobbe index is commonly expressed in Btu per standard cubic foot or megajoules per standard cubic meter (1000 BTU/scf = 37.3 MJ/m3). In the case of natural gas (molar mass 17 g/mol), the typical heating value is around 1,050 Btu per cubic foot and the specific gravity is approximately 0.59, giving a typical Wobbe index of 1,367.
There are three ranges or "families" of fuel gasses that have been internationally agreed based on Wobbe Index. Family 1 covers manufactured gases, family 2 covers natural gases (with high and low ranges) and family 3 covers liquefied petroleum gas (LPG). Combustion equipment is typically designed to burn a fuel gas within a particular family: hydrogen-rich Town Gas, Natural Gas or LPG.
| Family | Wobbe Index range (MJ/Sm3) | Type of gas |
| 1 | 22.5 – 30 | Town gas / Syn Gas |
| 2 L | 39 – 45 | Natural |
| 2 H | 45.5 – 55 | |
| 3 | 73.5 – 87.5 | LPG |
Other flame characteristics and composition limits may determine the acceptability of the replacement gas, e.g. flame speed, "yellow tipping" due to incomplete combustion, sulfur content, oxygen content, etc.
External links
Wikipedia content modification information:
- This page was last modified on 27 September 2008, at 23:45.
Wikipedia Authorship and Review
Wikipedia content provided here is not reviewed directly by MedLibrary.org. Wikipedia content is authored by an open community of volunteers and is not produced by or in any way affiliated with MedLibrary.org.
Wikipedia Usage Guidelines
This article is licensed under the GNU Free Documentation License. It uses material from the Wikipedia article on "Wobbe index".
The URL for this specific entry is:
All Wikipedia text is available under the terms of the GNU Free Documentation License. (See Copyrights for details). Wikipedia® is a registered trademark of the Wikimedia Foundation, Inc.