Choline C 11

CHOLINE C 11- choline c-11 injection
Mayo Clinic

1 INDICATIONS AND USAGE

Choline C 11 Injection is indicated for positron emission tomography (PET) imaging of patients with suspected prostate cancer recurrence and non-informative bone scintigraphy, computerized tomography (CT) or magnetic resonance imaging (MRI). In these patients, 11 C-choline PET imaging may help identify potential sites of prostate cancer recurrence for subsequent histologic confirmation. Suspected prostate recurrence is based upon elevated blood prostate specific antigen (PSA) levels following initial therapy. In clinical studies, images were produced with PET/CT coregistration.

Limitation of Use:11 C-choline PET imaging is not a replacement for histologic verification of recurrent prostate cancer.

2 DOSAGE AND ADMINISTRATION

2.1 Radiation Safety Drug Handling

Choline C 11 Injection is a radioactive drug and should be handled with appropriate safety measures to minimize radiation exposure during administration. Use waterproof gloves and effective shielding when handling Choline C 11 Injection. Radiopharmaceuticals, including Choline C 11 Injection, should only be used by or under the control of physicians who are qualified by specific training and experience in the safe use and handling of radioactive materials, and whose experience and training have been approved by the appropriate governmental agency authorized to license the use of radionuclides.

2.2 Recommended Dose and Administration Instructions

The recommended dose is 370 – 740 MBq (10 – 20 mCi) administered as a bolus intravenous injection. The radioactivity dose (370 – 740 MBq, 10 – 20 mCi) is chosen based on patient body dimensions and the characteristics of the image acquisition system

  • Inspect Choline C 11 Injection visually for particulate matter and discoloration before administration. Do not use the drug if the solution contains particulate matter or is discolored.
  • Aseptically withdraw Choline C 11 Injection from its container and administer the drug as a bolus through a peripheral venous catheter.
  • Dispose of any unused drug in a safe manner, in compliance with applicable regulations.

2.3 Patient Preparation

Prior to administration of Choline C 11 Injection:

  • Fasting for at least six hours is recommended to minimize the potential for dietary choline interference with radioactivity uptake in tissue.
  • Ensure that the patient is well hydrated and encourage voiding when imaging is completed.

2.4 R adiation Dosimetry

The estimated radiation absorbed doses for adults from intravenous injection of Choline C 11 Injection are shown in Table 1. These estimates are calculated from data in Tolvanen 1 and using OLINDA/EXM (Organ Level Internal Dose Assessment/Exponential Modeling) software from Vanderbilt University. 2

Table 1: Estimated Radiation Absorbed Dose Per Unit Activity for Adults, Choline C 11 Injection
Organ/Tissue Mean Absorbed Dose P er Unit Administered Activity ( μ Gy/MBq) b
Adrenals 3.59
Bone — Osteogenic Cells 4.81
Bone — Red Marrow 1.90
Brain 1.16
Breast 1.39
Gallbladder Wall 4.54
GI a – Lower Large Intestine Wall 1.81
GI a — Small Intestine 2.35
GI a — Stomach Wall 6.00
GI a – Upper Large Intestine Wall 6.41
Heart wall 3.43
Kidneys 20.62
Liver 20.11
Lungs 4.59
Muscle 2.54
Ovaries 2.02
Pancreas 29.19
Skin 1.22
Spleen 9.16
Testes 1.36
Thymus 1.69
Thyroid 1.49
Urinary Bladder Wall 3.41
Uterus 1.96
Total body 2.97
Effective Dose (μSv/MBq) c 4.35

a Gastrointestinal
b Assumed radiation weighting factor, w r , (formerly defined as quality factor, Q) of 1 for conversion of absorbed dose (Gray or rad) to dose equivalent (Sieverts or rem) for C 11. To obtain radiation absorbed dose in rad/mCi from the above table, multiply the dose in μGy/MBq by 0.0037, (e.g., 3.59 μGy/MBq × 0.0037 = 0.0133 rad/mCi).
c Radiation tissue weighting factors, w T , used in the calculation of effective dose are from 1990 Recommendations of the International Commission on Radiological Protection, ICRP Publication 60 (1991). To obtain radiation absorbed dose in rem/mCi from above table, multiply the dose in μGy/MBq by 0.0037, (e.g., 4.35 μGy/MBq × 0.0037 = 0.0161 rem/mCi).

The effective dose resulting from a 740 MBq (20 mCi) dosage of Choline C 11 Injection is 3.22 mSv in an adult, (740 × 4.35 = 3219 μSv = 3.2 mSv). The use of a CT scan to calculate attenuation correction for reconstruction of 11 C-choline images (as done in PET/CT imaging) will add radiation exposure. Based upon current scanning techniques, an effective dose of 5.8 mSv would be added from CT scanning. The actual radiation dose is operator, scanner, and patient dependent. The total radiation exposure from 11 C-choline administration and subsequent scan on a PET/CT scanner is estimated to be 9.0 mSv (3.2 mSv + 5.8 mSv).

Page 1 of 4 1 2 3 4

All MedLibrary.org resources are included in as near-original form as possible, meaning that the information from the original provider has been rendered here with only typographical or stylistic modifications and not with any substantive alterations of content, meaning or intent.

This site is provided for educational and informational purposes only, in accordance with our Terms of Use, and is not intended as a substitute for the advice of a medical doctor, nurse, nurse practitioner or other qualified health professional.

Privacy Policy | Copyright © 2024. All Rights Reserved.