Skyrizi (Page 11 of 13)
Instructions for Use
SKYRIZI ® (sky-RIZZ-ee) On-Body Injector
risankizumab-rzaa
injection, for subcutaneous use only
On-Body Injector and 180 mg/1.2 mL Prefilled Cartridge,
On-Body Injector and 360 mg/2.4 mL Prefilled Cartridge
Read this Instructions for Use before you start using SKYRIZI and each time you get a refill. There may be new information. This information does not take the place of talking to your healthcare provider about your medical condition or treatment.
Refer to the Medication Guide for SKYRIZI product information. Call your healthcare provider, call (866) SKYRIZI or (866) 759-7494 or go to SKYRIZI.com if you need help.
Important information you need to know before injecting SKYRIZI
- Receive training on how to inject SKYRIZI before giving an injection.
- Do not shake the SKYRIZI carton, On-Body Injector or prefilled cartridge.
- Do not remove the On-Body Injector or prefilled cartridge from the carton until you are ready to inject.
- Inject the medicine within 5 minutes after loading the cleaned prefilled cartridge into the On-Body Injector. Waiting will dry out the medicine and the On-Body Injector will not work afterwards.
- Do not touch the start button until you place the On-Body Injector loaded with the prefilled cartridge onto your skin and are ready to inject.
◦ You can only press the start button 1-time. - Do not use On-Body Injector or prefilled cartridge if either has been dropped or damaged.
- Do not reuse On-Body Injector or prefilled cartridge. The On-Body Injector and prefilled cartridge are for 1-time (single-dose) use only.
- Do not let the On-Body Injector get wet with water or any other liquids.
- This single-dose On-Body Injector is designed for use with SKYRIZI prefilled cartridge only.
- Physical activity should be limited during the injection process. Moderate physical activities can be done, such as walking, reaching and bending.
- Do not use SKYRIZI if the expiration date (EXP:) has passed.
- Do not use the prefilled cartridge if the liquid is cloudy or contains flakes or large particles. The liquid should look clear to yellow and may contain tiny white or clear particles.
- The On-Body Injector and the prefilled cartridge are not made with natural rubber latex.
- Keep SKYRIZI and all medicines out of the reach of children.
Storage and preparation for use
- Keep SKYRIZI in the original carton to protect from light and physical damage until time to use.
- Store SKYRIZI in your refrigerator between 36°F to 46°F (2°C to 8°C).
- When ready to use, take the carton out of the refrigerator and leave it at room temperature for at least 45 minutes up to 90 minutes to allow SKYRIZI to warm.
- Do not leave out in direct sunlight.
- Do not remove the On-body Injector or prefilled cartridge from the carton while allowing SKYRIZI to reach room temperature.
- Do not warm SKYRIZI in any other way. For example, do not warm it in a microwave or in hot water.
- Do not use if liquid has been frozen (even if thawed).
- Do not use SKYRIZI if carton perforations are broken. Return product to the pharmacy.
- Do not use the On-Body Injector and prefilled cartridge if the white paper tray seal is missing or damaged and return the carton to the pharmacy.
Get to know your SKYRIZI On-Body Injector and prefilled cartridge
Please read complete Instructions for Use before using SKYRIZI. Call your healthcare provider or (866) SKYRIZI or (866) 759-7494 or go to www.SKYRIZI.com if you need help or if you do not know how to proceed.
Step 1 Get ready | |
Before using SKYRIZI, you should receive training on how to inject SKYRIZI. | |
![]() | Check expiration date
|
![]() | Wait at least 45 minutes
|
![]() | Open the carton and remove the plastic tray
|
![]() | Gather all supplies and wash hands
|
![]() | Remove the white paper tray seal
|
![]() | Lift the plastic cover
|
Inspect the On-Body Injector
![]()
| |
Step 2 Set up On-Body Injector | |
Fully open the gray door ![]()
| |
Inspect the prefilled cartridge
| |
![]() | Clean the smaller bottom tip of the prefilled cartridge
|
![]() | Load the cleaned prefilled cartridge into the On-Body Injector
|
![]() | Close the gray door
|
Step 3 Prepare to inject | |
Keep electronic devices including cell phones at least 12 inches (30 cm) from On-Body Injector until injection is complete | |
![]() | Pick your injection area Locate a firm and flat area on your bare skin. Make sure the area is clear of clothing:
|
![]() | Clean the injection area
|
Peel both tabs to expose adhesive
![]()
| |
![]() | Prepare the On-Body Injector for placement
|
![]() | Place the On-Body Injector on your skin
|
Step 4 Inject medicine | |
Start injection
| |
![]() | Wait for the injection to finish
|
![]() | Injection is finished
|
![]() | Remove the On-Body Injector
![]()
|
Step 5 Confirm and dispose | |
![]() | Check the On-Body Injector
![]() |
![]() | Put the used On-Body Injector in an FDA-cleared sharps disposal container right away after use
|
Please read complete Instructions for Use before using SKYRIZI. Call your healthcare provider or (866) SKYRIZI or (866) 759-7494 or go to www.SKYRIZI.com if you need help or if you do not know how to proceed.
Commonly asked questions
Q. What if I cannot open the On-Body Injector door to insert the prefilled cartridge?
A. To open the On-Body Injector door, press in firmly on the left side of the door to release the door latch. If you are still unable to open the door, call (866) SKYRIZI or (866) 759-7494.
Q. What if I push the gray start button before I place the On-Body Injector on my skin?
A. The gray start button may be pressed just 1 time only. If the gray start button is pressed before placing it on your body, it can no longer be used. Call (866) SKYRIZI or (866) 759-7494.
Q. What if the On-Body Injector does not beep and the blue status light does not flash when I remove the green pull tabs?
A. Peeling off small green pull tab will remove the clear plastic strip, activating the On-Body Injector. If all of the adhesive paper has been removed and the On-Body Injector still does not turn on, call (866) SKYRIZI or (866) 759-7494.
Q. What if I push the start button as instructed after placing the On-Body Injector on the skin and the light remains blue?
A. Firmly press the gray start button again. If the status light remains blue or flashes red, remove the On-Body Injector by carefully peeling it away from your skin. Do not re-apply the On-Body Injector. Call (866) SKYRIZI or (866) 759-7494.
Q. What if the status light flashes red and beeps while wearing the On-Body Injector?
A. If the status light continuously flashes red and beeps, do not use the On-Body Injector. If it is attached to your body, carefully remove it. Call (866) SKYRIZI or (866) 759-7494.
Q. What should I do if the On-Body Injector comes off my body during the injection?
A. The loaded On-Body Injector can no longer be used. Do not re-apply it to your body. Call (866) SKYRIZI or (866) 759-7494.
Q. How do I know when the injection is complete?
A. The injection is complete when the On-Body Injector beeps, the white plunger has completely filled the medicine window, and the status light turns from flashing green to solid green.
Q. What should I do if there are more than a few drops of liquid on the injection area?
A. Call (866) SKYRIZI or (866) 759-7494 for help.
Q. What should I do with the used On-Body Injector after my injection?
A. Throw away (dispose of) used On-Body Injector in a FDA-cleared sharps disposal container and not your household trash. You can receive a sharps container for SKYRIZI disposal at no additional cost by going to www.SKYRIZI.com or by calling (866) SKYRIZI or (866) 759-7494.
Q. What if I have not received in-person training from a healthcare professional?
A. Call your healthcare provider or (866) SKYRIZI or (866) 759-7494 if you need help.
Disposing of SKYRIZI
- Put SKYRIZI in an FDA-cleared sharps disposal container right away after use. Do not throw away (dispose of) SKYRIZI in your household trash.
- If you do not have an FDA-cleared sharps disposal container, you may use a household container that is:
◦ made of a heavy-duty plastic,
◦ can be closed with a tight-fitting, puncture-resistant lid, without sharps being able to come out,
◦ upright and stable during use,
◦ leak-resistant, and
◦ properly labeled to warn of hazardous waste inside the container.
When your sharps disposal container is almost full, you will need to follow your community guidelines for the right way to dispose of your sharps disposal container. There may be state or local laws about how you should throw away used needles and syringes.
For more information about safe sharps disposal in the state that you live in, go to the FDA’s website at: www.fda.gov/safesharpsdisposal.
Do not recycle your used sharps disposal container.
Additional information
● Type BF applied part.
● On-Body Injector sterilized using ethylene oxide.
● Altitude range is -1,312 feet to 10,499 feet (-400 meters to 3,200 meters).
Electromagnetic Compatibility (EMC) of the On-Body Injector
The On-Body Injector is intended for home use or use in a professional healthcare environment and complies with ISO 11608-1:2014 and IEC 60601-1-2:2014.
Care should be taken to use the On-Body Injector within the following specific limits and environments to avoid adversely impacting the performance (missed or incomplete SKYRIZI dose).
- Keep electronic devices including cell phones at least 12 inches (30 cm) from the On-Body Injector until injection is complete. The potential impact of electronic interference is unknown when the On-Body Injector is operated within 12 inches (30 cm).
- Do not expose the On-Body Injector to Magnetic Resonance (MR) Environment (e.g., MRI).
- If it is used adjacent to other electrical equipment, observe the On-Body Injector and other equipment to ensure it is operating normally.
Emissions
Emissions test name | Test levels |
Radiated Radio frequency electromagnetic fields | Per CISPR 11, class B |
Electromagnetic Immunity
Test Name | Test Levels |
Electrostatic discharge (ESD) | ± 8 kV contact± 2 kV, ± 4 kV, ± 8 kV, ± 15 kV air |
Radio frequency electromagnetic field | 10 V/m 80 MHz – 2.7 GHz |
Power frequency 50 Hz magnetic field | 30 A/m |
The enclosure port immunity to RF wireless communications equipment complies with IEC 60601-1-2:2014.
Glossary of symbols
Symbol | Description of Symbol |
![]() | Keep dry |
![]() | Sterilized using ethylene oxide |
![]() | Do not re-use |
![]() | Do not use if package is damaged and consult instructions for use |
![]() | Date of manufacture |
![]() | Batch code |
![]() | Catalogue number |
![]() | Serial number |
![]() | Refer to instruction manual / booklet |
![]() | Type BF Applied Part |
![]() | MR Unsafe |
Manufactured by:
AbbVie Inc., North Chicago, IL 60064, U.S.A.
US License Number 1889
SKYRIZI® is a registered trademark of AbbVie Biotechnology Ltd.
©2022 AbbVie Inc. This Instructions for Use has been approved by the U.S. Food and Drug Administration.
Approved: 09/2022
20071101